Configuring the Actiontec M1000 modem in PPP mode for 1 IP address (/32) address:

The configuration for 1 static IP address is the same as it is for dynamic addressing. The difference is that our Radius server will assign your static IP address to your CPE each time you log on.

  1. Open your web browser and press your web browser's Stop button
  2. In the address bar enter the IP address of the Actiontec, by default it's http://192.168.0.1
  3. A page should load, showing the General Status
  4. Click on Quick Setup tab
  5. Scroll down to the bottom of the page and click on the link, Click here for advanced settings only if required by your ISP
  6. The Advanced Setup screen should appear
  7. Select the following:
    1. Step 1
      Select: PPoA
      Place a check in front of, PPP Auto Connect
    2. Step 2:
      Enter your PPP User Name and PPP Password
      (see Account information or Welcome letter for this)
    3. Step 3:
      * Select Single Static IP Address
      * In the Single Static IP box, enter the address provided to you
      (see Account information or Welcome letter for this, it should start with: 216.243.156.xxx)
      * If required, for the subnet mask, enter 255.255.255.255
      * If required, for the Default Gateway Address, enter the address that was provided to you
      (see Account information or Welcome letter for this)
    4. Step 4:
      * Select Static DNS addresses
      * Primary DNS: 65.193.16.1
      * Secondary DNS: 208.20.202.1
    5. Step 5:
      Leave VC-Mux (Default) selected
  8. Click Apply
  9. The screen will display a "Thank You" page when the process is complete
  10.  

The instructions and screen shots contained within this website are specific to services offered by Real Time Enterprises only.

 

 

Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.1 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts and no Back-Cover Texts. A copy of the license is included in the section entitled "GNU Free Documentation License".

Real Time Enterprises, Inc.

Real Time Enterprises, Inc.
10181 Crosstown Circle
Eden Prairie, MN 55344

Phone: (952) 943-8700
Fax: (952) 943-8500

Home
Open Linux Menu
Open Macintosh Menu
Open Windows Menu
Open Source Menu
Website Search
Send Email